Optex CVS2 Instruction Manual page 63

Table of Contents

Advertisement

External teaching cannot be performed.
BANK (Bank specification) may be set to "16".
• To permit the external teaching, set to "0" to "15".
The external bank switch input does not function.
BANK (Bank specification) may be set to "0" to "14".
• In order to use the external bank switch input, set to "15" or "16".
Output turns OFF even when the identity of the identity
bar graph is high.
ONESHOT (Oneshot output) may be set to "1".
• If set to "1", the output is already OFF.
The set value of ON DELAY (On delay time) may be long.
• When the On delay time is long, it takes time to turn ON.
OUTSIDE (Identity reversing) may be set to "1".
• If set to "1", the output turns OFF when the identity becomes over the
threshold value.
The external lighting does not turn ON correctly.
COMMUNIC (Communication setting) may be set to "1" to "5".
• Set to "0". When COMMUNIC (Communication setting) is set
at "1" to "5", the external lighting control signal is used as the
communication signal and the external lighting or remote monitor
cannot be used.
There I no difference in the operation of the sensor
with the set values "0" and "1" of ROTATE% (Rotation
correction tolerance).
Internally, the rotation correction tolerance is calculated by the
equation (Set value of ROTATE% × 256 / 360). Therefore "1", if set,
will be rounded down.
• There is no trouble with this sensor.
Set value cannot be changed.
The set value may be locked.
• If the set value is displayed in blue, it is at the LOCK (Change
prohibition) condition. To release the LOCK condition, display the
Ramco Innovations
www.optex-ramco.com
TROUBLESHOOTING
phone 800-280-6933
6
63