Function name
LCD display
Lighting ON/OFF
LIGHT ON
LCD Up/Down
reverse
LCDVIEW
Set value
initialization
enable
INITIALIZ
Communication
setting
COMMUNIC
Set value copy
BANKCOPY
★:Patent pending
56
Ramco Innovations
Setting range
(Initial value)
0
: Turns OFF internal lighting. (External
0, 1
lighting remains ON.)
(1)
1
: Turns ON internal lighting.
0
: Normal LCD display
1
: Displays the display of LCD display upside
0, 1
down (Image screen is not reversed.)Set to
"1" when mounting this device upside down.
(0)
The display of the remote monitor reverses
only the image screen.
When the device is powered ON with "15" set
as this set value and
same time, all the set values, registered screens,
0 – 15
brightness irregularity data are initialized.
(0)
10
: All set values will be locked.
11
: Locked condition of all set values is
released.
Sets communication function.
0
: Communication function is not used.
1-5
: Communication function is used.
1
0 – 5
3
5
(0)
Data length is 8 bit without parity bit, and stop
bit is 1bit.When using this communication
function, the external lighting remote monitor
function cannot be used.
Set values and registered screens of present bank
are copied to the bank of the target bank No. set
0 – 14
by this setting. During execution, imaging and
(0)
judgment are stopped. This set value will be "0"
when powered OFF.
www.optex-ramco.com
Explanation
and
: 4800 bps
2
: 9600 bps
: 19200 bps
4
: 38400 bps
: 57600 bps