SET UP

UNCRATING AND INSTALLATION

1. Location of the drill press should be in a well-lit area with correct power supply and that
will not interfere with other machines or operations.
2. Carefully uncrate machine and inspect all packing to make sure no parts are manuals
are thrown out.
3. When transporting the machine please use caution. If using a sling have someone
steady the machine while moving.
4. Install your drill press on a sturdy level floor surface. It must be anchored to the floor; the
machine is top heavy.
5. Connect appropriate power to the machine. Make sure circuit breakers are suitable for
the machine. Consult local codes for proper installation of machine. Always route power
cables in a safe manner away from traffic areas, damp areas, heat, and moving parts.
6. After installing the drill press, use degreasing product to clean off the anti-rust oil which
was applied at the factory. Then wipe machined surfaces with a light coating of lubricant
oil (way oil).
7. Check for damaged parts before further use of the machine. A guard or other part that is
damaged should be replaced or repaired before use. Carefully check to determine that it
will operate properly and perform its intended function. Check for alignment of moving
parts and binding od moving parts. Breakage of parts or mountings and or any other
conditions that could be affect its operation.

GROUNDING INSTRUCTIONS

In the event of a malfunction or breakdown, grounding provides a path of least resistance for
electric current to reduce the risk or electrical shock. This machine is equipped with an electric
cord must be used with a matching outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
• Do not modify the plug provided. If it will not fit the outlet have the proper outlet installed
by a qualified electrician.
• Improper connection of the equipment grounding can result in a risk of electrical shock.
The conductor with insulation having an outer surface that is green with yellow stripes is
equipment grounding conductor. If repair or replacement of the electric cord or plug is
necessary, do not connect the equipment grounding conductor to a live terminal.
• Check with a qualified electrician or serviceman if the grounding instructions are not
completely understood, or if in doubt as whether the machine is properly grounded.
• It is not recommended to use an extension cord or surge protectors on the machine.
• Ground fault circuit interrupters (GFCI) should not be used.
• Do not tamped with wiring or settings inside the frequency drive.
• Repaired or replace damaged or worn cords immediately.
977701V