Summary of Contents for Pilz PSEN 2.1p-41

  • Page 1 PSEN 2.1p-41 PSEN sensor technology Operating Manual-21735-EN-09...
  • Page 2 We do assure you that all persons are regarded without discrim- ination and on an equal basis. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    Requirements and connection to evaluation devices ............10 Installation ..........................13 Adjustment ..........................14 Periodic test ..........................15 Dimensions in mm .........................15 Technical details ........................16 Safety characteristic data......................17 Order reference ........................18 System ............................18 Accessories..........................18 EC declaration of conformity ....................19 UKCA-Declaration of Conformity ..................19 Operating Manual PSEN 2.1p-41 21735-EN-09...
  • Page 4: Introduction

    PSEN 2.1p-41 Introduction Validity of documentation This documentation is valid for the product PSEN 2.1p-41. It is valid until new documenta- tion is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5: Safety

    The following is deemed improper use in particular Any component, technical or electrical modification to the product, Use of the product outside the areas described in this operating manual, Use of the product outside the technical details (see Technical details [ 16]). Operating Manual PSEN 2.1p-41 21735-EN-09...
  • Page 6: Safety Regulations

    Damage can be attributed to not having followed the guidelines in the manual, Operating personnel are not suitably qualified, Any type of modification has been made (e.g. exchanging components on the PCB boards, soldering work etc.). Operating Manual PSEN 2.1p-41 21735-EN-09...
  • Page 7: Disposal

    The N/O contact is closed and the N/C contact is opened. The safety switch can be used in series connections. Operate the PSEN 2.1p-41 in conjunction with the following components: Actuator PSEN 2.1-20(see Order reference [...
  • Page 8: Block Diagram

    Block diagram Actuator Safety switch Magnet Operating distances (mm) omin Legend Assured operating distance Min. operating distance omin Assured release distance The offset-independent values for the switching distances are included in the Technical details [ 16]. Operating Manual PSEN 2.1p-41 21735-EN-09...
  • Page 9: Lateral And Vertical Offset

    = Max. overall cable resistance (see evaluation device's technical details) lmax Ri = Internal resistance sensor (see Technical details [ 16]) / km = Cable resistance/km of the cable (see technical details cable) l  Ensure the wiring and EMC requirements of EN 60204-1 are met. Operating Manual PSEN 2.1p-41 21735-EN-09...
  • Page 10: Pin Assignment

    [3+] black Requirements and connection to evaluation devices For use of PSEN 2.1p-41 in accordance with DIN EN 60947-5-3 an evaluation device must be connected. Connect the PSEN 2.1p-41 either with a certified Pilz evaluation device or with an evaluation device with defined properties...
  • Page 11 [ of PSEN 2.1p-41 – Always comply with the max. switching current safety contacts of PSEN 2.1p-41. Outputs at the evaluation device must only be switched on again when both reed con- tacts at the safety switch have been opened and closed (partial operation lock)
  • Page 12 33 34 43 44 11 12 21 22 31 32 41 11 12 21 22 33 34 43 44 PSENmag Fig.: Dual-channel connection of four PSENmag to the input circuits of an evaluation device Operating Manual PSEN 2.1p-41 | 12 21735-EN-09...
  • Page 13: Installation

    PSEN 2.1p-41 Examples for connection to Pilz evaluation devices: PNOZmulti PSENmag PSEN i1 brown white blue black Legend I0 Input OSSD I1 Input OSSD T1, T2 Test pulse outputs Installation CAUTION! Potential loss of safety function due to changed device properties The unit's properties may be affected if installed in an environment contain- ing electrically or magnetically conductive material.
  • Page 14: Adjustment

    Technical details [ 16]) can only be achieved by using the Pilz connection leads available as an accessory. If possible, do not install the safety switch and actuator on to ferromagnetic material. Changes to the operating distances are to be expected. In this case, use the spacer (see Order reference [ 19]).
  • Page 15: Periodic Test

    Carry out a monthly function test on the safety switch and actuator. Always test the function with the PSEN i1 interface and connected evaluation device. The safety function may only be checked by qualified personnel. Dimensions in mm Operating Manual PSEN 2.1p-41 | 15 21735-EN-09...
  • Page 16: Technical Details

    In accordance with the standard EN 60947-5-2 Acceleration Duration 11 ms Airgap creepage Pollution degree Rated insulation voltage 25 V Rated impulse withstand voltage 0,33 kV Protection type Housing IP65, IP67 Connector IP67 Operating Manual PSEN 2.1p-41 | 16 21735-EN-09...
  • Page 17: Safety Characteristic Data

    You must comply with the safety characteristic data in order to achieve the required safety level for your plant/machine. B10d in accordance with EN ISO 13849-1: 2015 TM [year] in accordance with EN ISO and EN 62061 13849-1:2015 2.000.000 Operating Manual PSEN 2.1p-41 | 17 21735-EN-09...
  • Page 18: Order Reference

    PSS67 Cable M8sf M12sm Female connector, M8 Male connector M12 380200 straight, 4-pin straight 380201 10 m 380202 30 m 380203 PSS67 Cable M8af M12sm Female connector M8 380204 angled, 4-pin 380205 10 m 380206 30 m 380207 Operating Manual PSEN 2.1p-41 | 18 21735-EN-09...
  • Page 19: Ec Declaration Of Conformity

    This product/these products meet the requirements of the directive 2006/42/EC for ma- chinery of the European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Authorised representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfildern, Germany UKCA-Declaration of Conformity This product(s) complies with following UK legislation: Supply of Machinery (Safety) Regu- lation 2008.
  • Page 20 We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...