Making Link Table Settings

1
In the Switcher >Link >Internal Bus Link menu, press [Link Table Select].
The Link Table Select menu appears.
2
Using any of the following methods, select the link source and link
destination signals.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs.
Knob
4
5
3
To confirm the selection, press [Link Src Set].
This links the link destination signal to the signal selected as Main No.
To initialize the set source address
In the Switcher >Link >Link Table Select menu, press [Init Link Table].
A confirmation message appears; press [Yes].
The source addresses are reassigned, and this is reflected in the status area.
To change the link number and link table number
In this menu too, you can change the link number and link table number. To do
this, turn the knobs as follows to make the setting, then press [Link Table Set].
Knob
1
3

Linking Cross-Point Buttons and GPI Output Ports

To link cross-point buttons or the [CUT] and [AUTO TRANS] buttons in the
cross-point control block, and GPI output ports, use the following procedure.
1
In the Switcher >Link menu, press [GPI Link], to display the Switcher
>Link >GPI Link menu.
The status area shows the output ports and the link status, and delay value
information.
Parameter
Adjustment
Main No
Video/key signal for link source
No
Video/key signal for link destination
Parameter
Adjustment
Link No
Link to which setting applies
Link Table No Link table selection
Setting values
1 to 64
1 to 8
Settings Relating to Function Links (Link Menu)
Setting values
1 to 128
1 to 128