VAT 612 Series Installation, Operating, & Maintenance Instructions page 8

Butterfly pressure control valve with cc-link interface, dn 63-250 (i.d. 2.5" - 10")
Table of Contents

Advertisement

Max. differential pressure on plate
Min. controllable conductance (C
[N
molecular flow]
2
Conductance in open position [N
Max. differential pressure on plate
Min. controllable conductance (C
(N
molecular flow)
2
Conductance in open position [N
Dimensions
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 612 DN 63-250 (I.D. 2.5" - 10"), CC-Link
Valve unit (continuation)
DN 63
2½"
(61236 - ....)
1000 mbar
)
0.45 l/s
min
molecular flow]
2
360 l/s
DN 250
10"
(61248 - ....)
100mbar
)
5 l/s
min
molecular flow]
15000 l/s
2
Refer to dimensional drawing of specific valve ordering number
(available on request)
DN 80
DN 100
3"
4"
(61238 - ....)
(61240 - ....)
1000 mbar
800 mbar
0.65 l/s
0.85 l/s
850 l/s
1400 l/s
DN 160
DN 200
6"
8"
(61244 - ....)
(61246 - ....)
300 mbar
150 mbar
1.7 l/s
2.8 l/s
3800 l/s
7800 l/s