VAT 612 Series Installation, Operating, & Maintenance Instructions page 58

Butterfly pressure control valve with cc-link interface, dn 63-250 (i.d. 2.5" - 10")
Table of Contents

Advertisement

GENERAL CONTROL SETPOINT bitmap table:
Bit
0
ZERO
1
NOT USED (reserved)
2
PING PONG TX BIT
3
NOT USED (reserved)
4
ACCESS MODE LOCKED
5-7
NOT USED (reserved)
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 612 DN 63-250 (I.D. 2.5" - 10"), CC-Link
0 = No Operation
1 = ZERO adjust, the actual pressure signal is set to internal pressure 0. The valid range for
adjustment is limited to -1.4V...+1.4! Otherwise the sensor must be adjusted!
-
PING PONG TX BIT transmitted from the master (PLC), is used to check the loop "master PLC -
VAT station". See chapter: 3.11.9
(PLC) and Station (Valve)
-
Start mode
local
locked
remote
Example:
1. from local to locked
1st step : set bit (01)
2. from local to remote
1st step : set bit (01)
2nd step: reset bit (10)
3. from remote to locked
1st step : set bit (01)
4. from locked to remote
1st step : reset bit (10)
-
Description
Communication and timing control between Master
Access mode locked bit
Set bit:
01
Reset bit: 10
Set bit:
01
End mode
locked
remote
locked
289856EA
58/85
2011-07-06