6.2 Opening and closing the units
6.2.1 About opening the units
6.2.2 To open the outdoor unit
6.2.3 To close the outdoor unit
ERLA03DAV3 + EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1 – 2019.10
At certain times, you have to open the unit. Example:
▪
When connecting the refrigerant piping
▪
When connecting the electrical wiring
▪
When maintaining or servicing the unit
DANGER: RISK OF ELECTROCUTION
Do NOT leave the unit unattended when the service cover is removed.
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING
NOTICE
When closing the outdoor unit cover, make sure that the tightening torque does NOT
exceed 1.3 N•m.
6
1×
2
2
1
1×
1
2
1
Unit installation
|
Installer reference guide