ERLA03DAV3 + EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1 – 2019.10
[8-02]: Anti-recycling time
1
0
1
0
[8-00]
[8-01]
1
Heat pump domestic hot water heating mode (1=active, 0=not active)
2
Hot water request for heat pump (1=request, 0=no request)
t
Time
Disinfection
Applies only to installations with a domestic hot water tank.
The disinfection function disinfects the domestic hot water tank by periodically
heating the domestic hot water to a specific temperature.
CAUTION
The disinfection function settings MUST be configured by the installer according to
the applicable legislation.
#
Code
[A.4.4.1]
[2‑01]
[A.4.4.2]
[2‑00]
[A.4.4.3]
[2‑02]
[A.4.4.4]
[2‑03]
[A.4.4.5]
[2‑04]
t
[8-02]
Disinfection
▪
0: No
▪
1: Yes
Operation day:
▪
0: Each day
▪
1: Monday
▪
2: Tuesday
▪
3: Wednesday
▪
4: Thursday
▪
5: Friday
▪
6: Saturday
▪
7: Sunday
Start time: 00~23:00, step: 1:00.
Temperature target: fixed value
Duration
Range: 40~60 minutes
9
Configuration
|
Description
Installer reference guide
127