Daikin Altherma 3 R F Installer's Reference Manual page 81

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

ERLA03DAV3 + EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1 – 2019.10
Item
Power consumption digital
inputs
Safety thermostat
Room thermostat (wired or
wireless)
Heat pump convector
Description
See
"8.3.10 To connect the power consumption
4
digital
inputs" [
 93].
See
"8.3.11 To connect the safety thermostat
(normally closed
contact)" [
See:
Installation manual of the wireless room
thermostat
Installation manual of the wired room
thermostat (digital or analogue) + multi-
zoning base unit
-
Connection of the wired room thermostat
(digital or analogue) to the multi-zoning
base unit
-
Connection of the multi-zoning base unit
to the indoor unit
Addendum book for optional equipment
Wires for wired room thermostat:
2×0.75 mm²
Wires for wireless room thermostat:
4×0.75 mm²
Maximum running current: 100 mA
For the main zone:
[A.2.1.7] Unit control method
[A.2.2.4] Contact type main
For the additional zone:
[A.2.2.5] Contact type add.
There are different controllers and setups
possible for the heat pump convectors.
For more information, see:
Installation manual of the heat pump
convectors
Addendum book for optional equipment
Wires: 4×0.75 mm²
Maximum running current: 100 mA
For the main zone:
[A.2.1.7] Unit control method
[A.2.2.4] Contact type main
For the additional zone:
[A.2.2.5] Contact type add.
8
Electrical installation
|
4
 94].
Installer reference guide
81

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehfz03s18dj3vErla03dav3

Table of Contents