Daikin Altherma 3 R F Installer's Reference Manual page 119

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

ERLA03DAV3 + EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1 – 2019.10
NOTICE
When adjusting the room temperature ranges, all desired room temperatures are
also adjusted to guarantee they are between the limits.
#
Code
Room temp. range
[A.3.2.1.2]
[3-06]
[A.3.2.1.1]
[3-07]
Room temperature step
ONLY applicable in room thermostat control and when the temperature is
displayed in °C.
#
Code
[A.3.2.4]
N/A
Room temperature hysteresis
ONLY applicable in case of room thermostat control. The hysteresis band around
the desired room temperature is settable. It is recommended NOT to change the
room temperature hysteresis as it is set for an optimal use of the system.
a
b
c
[ 9-0C ]
a
Room temperature
b
Actual room temperature
c
Desired room temperature
d
Time
#
Code
N/A
[9-0C]
Room temperature offset
ONLY applicable in case of room thermostat control. You can calibrate the room
temperature sensor. It is possible to give an offset to the room thermistor value
measured by the user interface. The settings can be used to compensate for
situations where the user interface cannot be installed on the ideal installation
location.
#
Code
Room temp. offset: Offset on the actual room temperature measured on the
user interface sensor.
[A.3.2.2]
[2-0A]
Description
Maximum temp (heating)
18°C~30°C
Minimum temp (heating)
12°C~30°C
Description
Room temp. step
1°C. The desired room temperature on the user
interface is settable per 1°C.
0.5°C. The desired room temperature on the
user interface is settable per 0.5°C. The actual
room temperature is displayed with an
accuracy of 0.1°C.
d
Description
1°C~6°C
Description
–5°C~5°C, step 0.5°C
9
Configuration
|
Installer reference guide
119