RECEIVER ROUTING
NORMAL
NORM 1 2 BOTH
ZONE NO: ‑
STOP
STOP
SET LOCKOUT CODE
SET LOCKOUT CODE
Digital Monitoring Products
30
RECEIVER ROUTING
This option displays if zone type is set for Auxiliary 1 or Auxiliary 2. Press any select area to
select the receiver routing for the selected zone.
Select NORM to send alarm and supervisory/trouble messages from this zone to receiver 1
or receiver 2 as programmed within the receiver in communications.
Select 1 to send alarm and supervisory/trouble messages from this zone to receiver 1 only,
regardless of the programming for the receiver in communications.
Select 2 to send alarm and supervisory/trouble from this zone to receiver 2 only, regardless
of the programming for that receiver in communications.
Select BOTH to send alarm and supervisory/trouble from this zone to both receivers,
regardless of the programming for either receiver in communications.
ZONE NUMBER
Enter the zone number you want to program next. Return to Zone Information and follow
the descriptions of each programming option. If all zones are programmed, press the back
arrow at the ZONE NO: – display to continue.
STOP
Press any select area to exit the programmer function of the communicator. When
selected, the communicator performs an internal reset and exits the programmer.
SET LOCKOUT CODE
Press CMD at the stop option to display SET LOCKOUT CODE. This feature allows you to
program a special code that will be required to gain access to the communicator's internal
programmer through the keypad.
Changing the Lockout Code
You can change this code at any time to any combination of numbers from 1‑5 digits long
(1‑65535). Do not use leading zeros for the lockout code.
1.
Press any select area. The keypad displays ENTER CODE: ‑ .
2.
Enter a 1‑5 digit code and press CMD.
Note: Do not enter a number higher than 65535.
3.
Enter the new lockout code you just entered in the keypad and press CMD.
The keypad displays CODE CHANGED.
Once you have changed the code, it is important that you write it down and store it in
a safe place. Lost lockout codes require the communicator to be sent back into DMP
for repair. You may cancel a lockout code by entering 00000 at the set lockout code
command option.