Chapter 3 Appendix
Error
Class
code
UEFI
1822
UEFI
1900
UEFI
1901
UEFI
1902
UEFI
1903
UEFI
1904
UEFI
1905
UEFI
1906
UEFI
1910
UEFI
1911
UEFI
1912
UEFI
1913
UEFI
1914
UEFI
1920
UEFI
1921
UEFI
1922
200
Error message
Slot %1 Encryption Failure - Imported
encrypted logical drives are offline.
Matching Local Master Key required.
System may not boot.
Slot %1 Smart Array - Controller
Failure. %2
Slot %1 Smart Array - Controller failed on
previous power-up due to lock up code
0x%2
Slot %1 Smart Array - Controller not
configured.
Slot %1 Smart Array - Memory error
occurred during self-test.
Slot %1 Smart Array - Redundant ROM
programming failure.
Slot %1 Smart Array - Redundant ROM
image checksum error. Backup ROM
activated.
Slot %1 Smart Array - Last configuration
not committed. %2
Slot %1 Smart Array - One or more drives
could not be authenticated as genuine
drives. Smart Array will not control the
LEDs to these drives.
Slot %1 Smart Array - Drive(s) are
failed: %2
Slot %1 Smart Array - Drive(s) are
overheated: %2
Slot %1 Smart Array - Drive Erase
Operation In Progress (or Queued). The
following drive(s) will be erased upon
completion: %2
Slot %1 Smart Array - Predictive drive
failure: %2
Slot %1 Smart Array - Storage enclosure
problem detected: %2. %3
Slot %1 Smart Array - Storage enclosure
firmware problem detected: %2. %3
Slot %1 Smart Array - More devices
attached than this controller supports.
Some devices are ignored.
Express5800/R120h-1E, R120h-2E Maintenance Guide
Action
Enter the local master key using the Smart Storage
Administrator.
Please take actions in following order.
1. After turning off the unit power and disconnecting the
power cord, check the installation of the Slot% 1
controller (card). Wait 30 seconds, and then restart it.
2. If the problem persists, contact your sales
representative.
Contact your sales representative.
Check the connection between the Slot% 1 controller
(card) and back plane and hard disk drive. Configure
the drive using the Smart Storage Administrator.
Contact your sales representative.
Updating the firmware of the Slot% 1 controller (card) to
the latest version may solve the error. Please update
the corresponding firmware. If the problem persists,
contact your sales representative.
Updating the firmware of the Slot% 1 controller (card) to
the latest version may solve the error. Please update
the corresponding firmware. If the problem persists,
contact your sales representative.
Set the configuration of the Slot% 1 controller again.
The hard disk drive connected to the Slot% 1 controller
(card) could not be verified as an authorized part. To
confirm the corresponding hard disk drive, check it via
the Smart Storage Administrator.
Contact your sales representative.
Contact your sales representative.
Action is not necessary.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Please take actions in the following order.
1. Updating the firmware of the Slot% 1 controller to the
latest version may solve the error. Refer to the release
notes to check if there are related improvements. If
there are related improvements, update the firmware of
the Slot% 1 controller.
2. Reduce the number of hard disk drives connected to
the Slot% 1 controller.
1. IML Error Message