NEC Express5800 Series Maintenance Manual page 192

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error
Class
code
UEFI
372
UEFI
373
UEFI
374
UEFI
375
UEFI
376
UEFI
377
UEFI
378
UEFI
379
UEFI
380
UEFI
381
192
Error message
IMPORTANT: Processor %1, DIMM %2.
New NVDIMM detected and has been
disabled.
IMPORTANT: NVDIMM(s) have been
removed from Processor %1. All NVDIMMs
on Processor %2 have been disabled.
NVDIMM Error - Processor %1, DIMM %2
(SN:%3-%4-%5-%6) received a memory
initialization or uncorrectable error. All
NVDIMMs on Proc %7 are disabled. Data
on NVDIMM may have been lost
NVDIMM Error - Processor %1, DIMM %2
(SN:%3-%4-%5-%6) received a memory
initialization or uncorrectable error.
NVDIMM has been disabled. Data on
NVDIMM may have been lost.
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM set for interleaving disabled but
system configured for interleaving enabled.
All NVDIMMs on Processor %3 are
disabled.
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM set for interleaving enabled but
system configured for interleaving
disabled. NVDIMM has been disabled.
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM is configured for a different
processor type. All NVDIMMs on
Processor %3 are disabled.
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM is configured for a different
processor type. NVDIMM has been
disabled.
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM location changed. All NVDIMMs
on Processor %3 are disabled.
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM location changed. NVDIMM has
been disabled.
Express5800/R120h-1E, R120h-2E Maintenance Guide
Action
Sanitize the NVDIMM connected to the corresponding
processor. If the problem persists, contact your sales
representative.
Please take actions in following order.
1. Sanitize the NVDIMM connected to the
corresponding processor.
2. If the problem persists, contact your sales
representative.
Please take actions in following order.
1. Sanitize the NVDIMM.
2. Contact your sales representative.
Please take actions in following order.
1. Sanitize the NVDIMM.
2. Contact your sales representative.
Set NVDIMM Interleaving to Disabled, or sanitize the
NVDIMM. If the problem persists, contact your sales
representative.
Set NVDIMM Interleaving to Enabled, or sanitize the
NVDIMM. If the problem persists, contact your sales
representative.
Sanitize the NVDIMM. If the problem persists, contact
your sales representative.
Sanitize the NVDIMM. If the problem persists, contact
your sales representative.
Install the NVDIMM in the corresponding DIMM slot, or
sanitize the NVDIMM. If the problem persists, contact
your sales representative.
Install the NVDIMM in the corresponding DIMM slot, or
sanitize the NVDIMM. If the problem persists, contact
your sales representative.