Menu Tree Of Hpe Smart Array S100I Utility - NEC Express5800 Series Maintenance Manual

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 2 Useful Features
2.3

Menu Tree of HPE Smart Array S100i Utility

Menu
Controller Information
UEFI Driver version
UEFI Driver release date
Firmware version
Firmware release date
PCIe device ID
PCIe Slot number
Configure Controller Settings
> Modify Controller Settings
Rebuild Priority
Surface Scan Analysis Priority
Current Parallel Surface Scan Count
Physical Drive Write Cache State
Spare Activation Mode
Port1I Mode
Port 2I Mode
Port 3I Mode
Port 4I Mode
Port 5I Mode
Port 6I Mode
> Advanced Controller Settings
Degraded Mode Performance
Optimization
Physical Drive Request Elevator Sort
Maximum Drive Request Queue Depth
Monitor and Performance Analysis
Delay
HDD Flexible Latency Optimization
> Clear Configuration
Default Value
Low
3
1
Disabled
Failure Spare
Activation
RAID
RAID
RAID
RAID
RAID
RAID
Disabled
Enabled
Automatic
60
Disabled
Express5800/R120h-1E, R120h-2E Maintenance Guide
2. RAID System Configuration
Descriptions
UEFI Driver version
UEFI Driver release date
Firmware version
Firmware release date
PCIe device ID
PCIe Slot number
Priority at which the logical drives are rebuilt
from the failed state. It can be low, medium,
medium high or high.
0:Disable. 31:High. 1-31:Idle(with
delay).Modifies the amount of delay/idle time of
the controller before the surface scan analysis
is resumed again.
Set the maximum number of surface scans that
can run at the same time. Setting 1 disables the
feature.
Option for enabling the write cache on the
physical drives.
Option to change between the failure or
predictive spare activation modes.
Connector Mode: For multiple domain
connections.
Connector Mode: For multiple domain connections.
Connector Mode: For multiple domain connections.
Connector Mode: For multiple domain connections.
Connector Mode: For multiple domain connections.
Connector Mode: For multiple domain connections.
Parity RAID Degraded Mode performance
optimization.
It enables or disables the physical drive cache
write elevator sort algorithm.
The maximum number of physical drive
requests the firmware will submit to a drive at a
given time.
0-1440: input range. 60: Default. Set the
monitor and performance analysis delay.
Enables or Disables the flexible Latency
scheduler to limit the high latency request from
the HDDs.
Removes the controller meta-data, array
information and partition information.
141