NEC Express5800 Series Maintenance Manual page 194

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error
Class
code
UEFI
394
UEFI
395
UEFI
396
UEFI
397
UEFI
398
UEFI
399
UEFI
400
UEFI
401
UEFI
402
UEFI
403
UEFI
410
194
Error message
NVDIMM Error - Processor %1, DIMM %2
(SN:%3-%4-%5-%6). Unable to set event
notification for this NVDIMM to generate
alerts for health changes, including a loss
of data persistency.
NVDIMM Error - Processor %1, DIMM %2
(SN:%3-%4-%5-%6). NVDIMM
Persistency is lost and future data backup
is not available.
IMPORTANT: Processor %1, DIMM %2 -
NVDIMM Persistency is restored and
future data backup is available.
WARNING: Processor %1, DIMM %2
(SN:%3-%4-%5-%6). NVDIMM lifetime has
been reached.
NVDIMM Configuration Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). Backup power is not
available to this DIMM slot. NVDIMM is
disabled.
INFORMATION: Processor %1, DIMM %2
(SN:%3-%4-%5-%6). Extended Diagnostic
Information (Data1 = 0x%7, Data2 = 0x%8,
Data3 = 0x%9, Data4 = 0x%10).
Intrusion Alert Detection - The server
chassis hood is currently not installed.
Intrusion Alert Detection - The server
chassis hood was removed prior to this
power on.
Intrusion Alert Detection - The required
intrusion detection cable is missing.
Intrusion Alert Configuration Error -
Intrusion Alert Detection cable is installed
but the feature is not enabled.
Innovation Engine Error - The Innovation
Engine is not operating properly. (Error
Code %1).
Express5800/R120h-1E, R120h-2E Maintenance Guide
Action
Updating the system ROM and the innovation engine
firmware may solve the error. Please update the system
ROM and the innovation engine firmware.
If the problem persists, contact your sales
representative.
Please take actions in following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
Action is not necessary.
Please take actions in following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
Install the NVDIMM in the slot where the NVDIMM is
available. If the problem persists, contact your sales
representative.
Action is not necessary.
However, if the error is recorded repeatedly, please
contact your sales representative.
An intrusion warning has been detected. The cover of
the server has not been installed. Check the installation
of the cover.
If the problem persists, contact your sales
representative.
An intrusion warning has been detected. It detected that
the server cover has been once removed. Check the
status of the server.
If the problem persists, contact your sales
representative.
An intrusion warning has been detected. The intrusion
detection cable is not connected. Check the status of
the server.
If the problem persists, contact your sales
representative.
An intrusion warning has been detected. While the
intrusion detection cable has been connected, its
function is not enabled. Check the settings of the server.
If the problem persists, contact your sales
representative.
Updating the system ROM and the innovation engine
firmware may solve the error. Please update the system
ROM and the innovation engine firmware.
If the problem persists, contact your sales
representative.
1. IML Error Message

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/r120h-1eExpress5800/r120h-2eExp336Exp337

Table of Contents