Error message
NVDIMM Error - Proc %1, DIMM %2 is
NOT configured for Sub-NUMA Clustering
but system is configured for Sub-NUMA
Clustering. All NVDIMMs on Proc %3 are
disabled.
NVDIMM Error - Proc %1, DIMM %2 is
configured for Sub-NUMA Clustering but
system is NOT configured for Sub-NUMA
Clustering. All NVDIMMs on Proc %3 are
disabled.
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM set for Channel Interleaving
disabled but system configured for
enabled. All NVDIMMs on Processor %3
are disabled.
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM set for Channel Interleaving
enabled but system configured for
disabled. All NVDIMMs on Processor %3
are disabled.
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM Metadata is corrupted. All
NVDIMMs on Processor %3 are disabled.
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM Metadata is corrupted. NVDIMM
is disabled.
Uncorrectable Memory Error - The failed
memory module could not be determined.
NVDIMM Configuration Error - Node
Interleaving is Enabled. This is NOT
supported with NVDIMMs installed. All
NVDIMMs are disabled.
NVDIMM Configuration Error - The
Advanced Memory Protection mode is not
Advanced ECC. Only Advanced ECC is
supported with NVDIMMs. All NVDIMMs
are disabled.
IMPORTANT: New NVDIMM(s) detected
and all NVDIMMs have been disabled.
Express5800/R120h-1E, R120h-2E Maintenance Guide
Action
Set Sub-Numa Clustering to Disabled, or sanitize the
NVDIMM. If the problem persists, contact your sales
representative.
Set Sub-Numa Clustering to Enabled, or sanitize the
NVDIMM. .If the problem persists, contact your sales
representative.
Set Channel Interleaving to Disabled, or sanitize the
NVDIMM. If the problem persists, contact your sales
representative.
Set Channel Interleaving to Enabled, or sanitize the
NVDIMM. If the problem persists, contact your sales
representative.
Sanitize the NVDIMM. If the problem persists, contact
your sales representative.
Sanitize the NVDIMM. If the problem persists, contact
your sales representative.
Contact your sales representative.
Set Node Interleaving to Disabled. If the problem
persists, contact your sales representative.
Set Advanced Memory Protection to Advanced ECC
Support. If the problem persists, contact your sales
representative.
Sanitize the NVDIMM. If the problem persists, contact
your sales representative.