NEC Express5800 Series Maintenance Manual page 190

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error
Class
code
UEFI
343
UEFI
344
UEFI
345
UEFI
346
UEFI
351
UEFI
352
UEFI
353
UEFI
354
190
Error message
IMPORTANT: NVDIMM backup power has
been lost and a future backup is not
possible. Data from the last successful
backup is intact, but data modified after the
last successful backup will be lost if power
cannot be restored.
NVDIMM Error - NVDIMM Controller Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). An error was found
with the NVDIMM controller. The OS will
not use the NVDIMM. Data from last
successful backup is still available, but will
be lost if controller error persists.
NVDIMM Error - Erase Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). NVDIMM could not
be erased by the NVDIMM controller FW
and future backups are not possible.
NVDIMM Error - Arming Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). NVDIMM could not
be armed and future backups are not
possible.
IMPORTANT: %1 is not charged sufficiently
to support the energy-backed persistent
memory installed in the system. The
system will wait for the battery to charge
sufficiently before continuing boot.
IMPORTANT: %1 is not charged sufficiently
to support the energy-backed persistent
memory installed in the system. System
configured to not wait for battery to charge.
Persistent memory regions may not be
available in the OS.
IMPORTANT: Possible Password
Corruption. The PW authentication
algorithm detected an issue which has
been corrected.
Unsupported NVDIMM-N Configuration
Detected - Processor %1 DIMM %2. The
installed NVDIMM-N is not supported.
Express5800/R120h-1E, R120h-2E Maintenance Guide
Action
Check the backup power supply of the NVDIMM. Back
up the contents recorded in the NVDIMM to other media
to protect the data. If the problem persists, contact your
sales representative.
Please take actions in the following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
Please take actions in the following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
Please take actions in the following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
Perform one of the following actions.
1. Wait until the battery is fully charged so that the unit
can continue to be operated.
2. Press the <ESC> key to continue operating without
waiting for the battery fully charged.
Perform one of the following actions.
1. Wait until the battery is fully charged so that the unit
can continue to be operated.
2. Change to the setting where the unit operation is
suspended until the battery is fully charged.
Reset your password. To clear the currently set
password, follow the procedure in Chapter 1 (7.
Resetting and Clearing the Server) in this manual.
If the problem persists, contact your sales
representative.
A connection of unavailable NVDIMM-N has been
detected. Check the installation of the NVDIMM - N. If
the problem persists, contact your sales representative.