Specifications - Sanyo Denki SANUPS E11A Series Instruction Manual

Hybrid, 1kva, 1.5kva, 2kva, 3kva, 100v
Hide thumbs Also See for SANUPS E11A Series:
Table of Contents

Advertisement

§
1
7
.
4
S
p
e
c
i
f
i
§
1
7
.
4
S
p
e
c
i
f
i
Item
E11A102U
MODEL
001-20 001-00
E11B102
TYPE
001US
Output capacity
1kVA/0.7kW
Cooling system
Input plug
Phases
120V
-20% to +15%: Double conversion mode operation
Voltage
±5%: Economy or Active Filter mode operation when Auto is set.
±8%: Economy mode operation when Economy is set.
Frequency
Power requirements
0.9kVA
Input power factor
Outlet
NEMA 5-15R×6
Phases
Voltage
120V
Voltage regulation
Rated frequency
Battery power startup
60Hz
frequency
Rated frequency within ±1%: Double conversion setting.
Frequency regulation
Rated frequency within ±1%, ±3% or ±5%: Auto or Economy setting.
Voltage waveform
Distortion factor of
voltage waveform
Rapid load
change
Transient
Power outage,
voltage
recovery
variation
Rapid input
voltage change
Response time
Load power factor (lag)
Overcurrent protection
Inverter
Overload
capability
Bypass
Type
Number
Rated capacity
Backup time
Generated heat
Input leakage current
Operating environment
Acoustic noise
Safety standard
UL1778-4th/C22.2 No.107.3-05-2nd, CE: IEC62040-1:2008
EN62040-2 C2:2006
Emission
FCC Part15 Sub partB Class-A, EN55022:2006 Class-A
Immunity
EN62040-2:2006, EN55024:1998/A1:2001/A2:2003
(*1) The inverter is capable of operation synchronized with AC input frequency and instantaneous switchover provided that the
AC input frequency is within the rated frequency, and the AC input voltage is within the rated voltage.
(*2) When input voltage waveform distortion is under 1%.
(*3) The UPS contains batteries. Battery service life will be foreshortened if the UPS is used in an environment where the ambient
temperature exceeds 30°C (86°F).
(*4) If grounded, the ground phase of the input and output must match according to UPS specifications.
(*5) The above table lists standard specifications. Some specifications are different for units with long backup times. For details,
refer to the external battery specification instruction manual.
(*6) Voltage settable function is available for the and E11A*U-J model only. Default setting is 100V. E11A*U model is designed for
a 120V AC power supply. This Model is authorized as UL Model.
(*7) Output capacity of E11A302U-J model varies depending on the setting of output voltage as below.
Output voltage Settings
100V
110V
115V
120V
(*8) During Double Conversion mode operation. When UPS operates in Economy mode or Active Filter mode, these depend on
utility power.
c
a
t
i
o
n
s
c
a
t
i
o
n
s
Standard or Performance
E11A152U
001
001J
E11A152B
001UJ
001US
001UJ
001US
1.5kVA/1.05kW
2 kVA/1.4kW
Forced air cooling
NEMA 5-15P
NEMA 5-20P
Single phase, 2-wire
120V
120V
See Notes
See Notes
50Hz or 60Hz
1.36kVA
0.95 or more
NEMA 5-20R×4
Single phase, 2-wire
120V
120V
See Notes
See Notes
Rated voltage 2%
50Hz or 60Hz
50Hz
60Hz
50Hz
60Hz
Sine wave
Linear load: 3% or less
100% rectifier load: 7% or less
Rated voltage 5 %
5 cycles or less
0.7 (lag)
Auto switch to bypass circuit at 105% or more
105%
15A
20A
(supplementary breaker)
Small-sized valve regulated lead-acid battery
2
3
68W
102W
5 minutes
125W
200W
3mA or less
Ambient temperature: 0 to 40°C (32 to 104°F)
Relative humidity: 20 to 90%
40 dB or less
EN62040-2 C3:2006
Output capacity
2.5kVA/1.75kW
2.75kVA/1.925kW
2.875kVA/2.013kW
3kVA/2.1kW
E11A202U
E11A302U
001
001J
001
001J
E11A202B
E11A302B
001UJ
001US
001UJ
3 kVA/2.1kW
NEMA L5-30P
120V
See Notes
See Notes
1.8kVA
2.7kVA
NEMA L5-30R
120V
See Notes
See Notes
50Hz
60Hz
50Hz User settable
(*8)
(*8)
25A
40A
4
5
136W
170W
3.5 minutes
250W
460W
45 dB or less
Characteristics
Notes
100,110,115,120V: User settable (*6)
(Rated voltage same as output voltage)
8%: Double Conversion mode
1, 3, 5%: Economy /Active Filter mode
Max. capacity during battery charging
During rated output
100,110,115,120V: User settable (*6)
During Double Conversion mode operation
Same as input frequency (auto selection)
1, 3, 5% selectable
UPS free running operation 0.5%
During rated output
0%
100% at transient or output switch
During rated output
10% variation
Variation range 0.7 (lag) to 1.0
With auto return function
200ms
200% 30 sec., 800% 2 cycle (reference)
12V per battery, series
15 minute-rate
At 25°C (77°F) ambient temperature, rated
load
During Double Conversion mode operation
1 m (approx. 40 inches) from UPS front
panel, 'A' characteristics (linear load)
At Economy mode operation
(*7)
(*2)
(*3)
46