SECTION 6 – GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
6.10 TILT SENSOR VERIFICATION
Interval - At least every 6 month of operation.
1. Drive the machine on a known level surface.
2. Chock both rear wheels.
3. Remove chassis hoods and place a spirit level (digital
display) on the chassis positioned in line w/chassis.
4. Using a jack of appropriate capacity, lift the front on the
chassis. The tilt alarm must be activated within 0.2°
below the value in Table 6-1.
5. Place the spirit level perpendicular to the chassis and lift
either the left or the right side of the chassis. The tilt
alarm must be activated within 0.2° below the value in
Table 6-1.
6. If the tilt warning is not activated within the indicated
angle values, the tilt sensor must be recalibrated by a
qualified technician before replacing machine into ser-
vice.
6-28
Figure 6-17. Jacking Points
– JLG Lift –
31210162