DTC
FAULT MESSAGE
SLAVE MODULE
427
TEMPERATURE - OUT OF
RANGE
MASTER MODULE TOO HOT -
428
PLEASE WAIT
SLAVE MODULE TOO HOT -
429
PLEASE WAIT
RIGHT DRIVE MOTOR TOO HOT
4210
- PLEASE WAIT
LEFT DRIVE MOTOR TOO HOT -
4211
PLEASE WAIT
RIGHT DRIVE MOTOR
4212
TEMPERATURE - OUT OF
RANGE
31210162
SECTION 6 – GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
DESCRIPTION
The Slave Module (left controller) temperature
sensor is out of the permitted range.
The Master Module (right controller) has reached
thermal cutout.
The Slave Module (left controller) has reached
thermal cutout.
The right drive motor temperature is too high.
The left drive motor temperature is too high.
A problem has been detected in this function.
– JLG Lift –
CHECK
Refer problem to a qualified JLG mechanic.
• Power down and allow to cool.
• Do not operate in ambients over 60°C (140°F).
Refer problem to a qualified JLG mechanic.
• Power down and allow to cool.
• Do not operate in ambients over 60°C (140°F).
Refer problem to a qualified JLG mechanic.
• Power down and allow to cool.
• Do not operate in ambients over 60°C (140°F).
Refer problem to a qualified JLG mechanic.
• Power down and allow to cool.
• Do not operate in ambients over 60°C (140°F).
Refer problem to a qualified JLG mechanic.
Refer problem to a qualified JLG mechanic.