SECTION 3 – MACHINE CONTROLS AND INDICATORS
1. 5 Amp. Circuit Breaker - This circuit breaker protects
the control circuit in case of a short circuit or other mal-
function.
2. Overload Warning Light (if equipped) - This lamp
(red), when blinking, indicates that the maximum rated
load in the platform is exceeded. The platform must be
safely unloaded until the alarm stops.
3-4
3. Multi-Display Indicator (MDI)
Hourmeter - The hourmeter symbol is lit when
the number of operated hours is displayed.
Speed reduction - Indicates that the maximum
drive speed is reduced when the platform is
out of transport position.
The wrench symbol is lit when a DTC (Diagno-
sis Troubleshooting Code) is displayed.
Five Digits Display
In normal operating condition, displays the
total amount of machine operation time accu-
mulated.
In abnormal operating condition, displays a
DTC (Diagnosis Troubleshooting Code).
Alarm LED
Illuminates in abnormal operating condition
(when a DTC, other than 00xx DTC's, exists).
Battery Discharge Indicator (BDI).
This bar-graph is designed to let the operator
know the condition of the battery before start-
ing to use the machine.
The last bar flashes when the level of charge is
less than 10%. The bar-graph is not displayed
when the batteries are completely discharged.