VERSION 07/2014
OPERATING MANUAL
6.8.4

FILLING WITH WORKING MATERIAL

Positions of the ball valve
1
Open: working position
2
Closed: The air motor can still be under pressure.
3
Vent: Operating pressure in the air motor is
vented (control pressure is still present).
1
Place suction hoses (7a and 7b) with return tubes
(4a and 4b) in the tanks with working material
(6a) and hardener (6b).
2
Adjust the pressure regulator (1) to
approx. 0.05 MPa; 0.5 bar; 7.25 psi.
3
Open relief valves (3a and 3b).
4
Slowly open the ball valve (2).
5
Adjust the air pressure on the pressure
regulator (1) so that the pump runs smoothly.
6
Close ball valve (2) as soon as pure working
material starts coming from the return hoses (4a
and 4b)
7
Turn relief valves (3a and 3b) in spraying position
(to the mixer (9) leading).
8
Point the gun (8), without nozzle, into empty
tank (5a) and open it.
9
Slowly open the ball valve (2).
10 Close ball valve (2) as soon as pure working
material starts coming from the gun.
11 When there is no pressure remaining in the
system, close the gun.
12 Secure the gun.
ORDER NUMBER DOC2349980
3
2
1
B
B_04301
A
B_03118
34