Panasonic SC-HG1 Series Reference Manual page 90

For mitsubishi melsec iq-r series sequencer
Table of Contents

Advertisement

Error code
■ List of error codes
Error code
(hexadecimal)
The Station No. (i_uStationNo) is
100
outside the valid range
The information derived from the input
Start I/O No.(i_uStartIONo) and the
101
Station No. (i_uStationNo) is not
SC-HG1-C or SC-HG1-CEF.
Set to a controller where Set Controller
104
(i_uSetController) is set to 0 or does not
exist
The Low Threshold (i_dLowThreshold)
10F
value is higher than the High Threshold
(i_dHighThreshold) value.
Low Threshold (i_dLowThreshold) is
110
outside the valid range
High Threshold (i_dHighThreshold) is
111
outside the valid range
Hysterisis Value (i_udHysteresis) is
112
outside the valid range
Hysterisis Value (i_udHysteresis) is
larger than the difference between Low
113
Threshold (i_dLowThreshold) and High
Threshold (i_dHighThreshold)
Description
SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
For CC-Link master/local module
Set the Station No. (i_uStationNo) to a value from 1 to 64.
For CC-Link IE Field master/local module
Set the Station No. (i_uStationNo) to a value from 1 to 120.
Check if the Start I/O No.(i_uStartIONo) and the Station
No. (i_uStationNo) settings correctly indicate the target
communication unit.
Make the value of Set Controller (i_uSetController) greater
than 0.
Check if the setting is not applied to a controller beyond
the maximum number of connected units. Also, check if the
15th bit of Set Controller (i_uSetController) is not ON.
Correct the settings so that the Low Threshold
(i_dLowThreshold) value is lower than the High Threshold
(i_dHighThreshold) value.
Specify a value within the valid range.
Specify a value within the valid range.
Specify a value within the valid range.
Make Hysterisis Value (i_udHysteresis) smaller than the
difference between Low Threshold (i_dLowThreshold) and
High Threshold (i_dHighThreshold)
90/184
Meaning
WUME-SCHG1IQRFB-1

Advertisement

Table of Contents
loading