Panasonic SC-HG1 Series Reference Manual page 57

For mitsubishi melsec iq-r series sequencer
Table of Contents

Advertisement

Error code
(hexadecimal)
200
Remote READY flag OFF
Execution Command (i_bEN) turned OFF
201
before normal or error completion
Execution Command (i_bEN) was turned
from ON to OFF and then turned from
202
OFF to ON while Execution Status
(o_bENO) was ON
FFFF
Module error occurrence
Description
SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
Check whether or not an error has occurred in the
communication unit.
Check if the Start I/O No.(i_uStartIONo) and the Station
No. (i_uStationNo) settings correctly indicate the target
communication unit.
Check that Normal Completion (o_bOK) or Error
Completion (o_bErr) has turned ON and then turn OFF
Execution Command (i_bEN). This error code is output
also when Execution Command (i_bEN) is intentionally
turned OFF before completion.
Check that Execution Status (o_bENO) turned OFF and
then turn ON Execution Command (i_bEN).
Check the Module Error Code (o_ud16ModuleErrId).
For information on module error codes, see "Appendix
2.4 Module error code (o_u16ModuleErrId) list".
57/184
Meaning
WUME-SCHG1IQRFB-1

Advertisement