Panasonic SC-HG1 Series Reference Manual page 116

For mitsubishi melsec iq-r series sequencer
Table of Contents

Advertisement

Name
Alarm Delay
Alarm Threshold
Reset Flag
■ Output labels
Name
Execution Status
Normal Completion
Error Completion
Error Code
Module Error Code
Read Alarm Delay
Read Alarm Threshold
Variable name
Word
i_uAlarmDelay
[Unsigned]
Double word
i_dAlarmThreshold
[Signed]
i_bReset
Bit
Variable name
o_bENO
o_bOK
o_bErr
o_uErrId
o_ud16ModuleErrId[n]
o_u15ReadAlarmDelay[n]
o_d15ReadAlarmThreshold[n]
SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
Data type
Valid range
1 to 1000
-1999999 to 1999999
ON, OFF
Data type
Default
Bit
OFF
Bit
OFF
Bit
OFF
Word
[Unsigned]
Double
word
[Unsigned]
Word
[Unsigned]
Double
word
[Signed]
116/184
Set the alarm delay.
Set the alarm threshold.
Starting the FB with this flag ON
resets the alarm setting.
Description
Stays ON while the FB is running.
Turns ON upon normal completion of the
FB.
Turns ON upon error completion of the FB.
Stores the error code that occurred in the
0
FB.
Stores the error code that occurred in the
communication unit.
16 arrays exist and store module error
codes.
0
n=0: Master device
n=1: 1st slave device
to
n=14: 14th slave device
n=15: Communication unit
15 arrays exist and store Read Alarm Delay
values.
n=0: Master device
0
n=1: 1st slave device
to
n=13: 13th slave device
n=14: 14th slave device
15 arrays exist and store Read Alarm
Threshold values.
n=0: Master device
0
n=1: 1st slave device
to
n=13: 13th slave device
n=14: 14th slave device