Labels To Be Used
■ Input labels
Name
Execution Command
CC-Link IE Field flag
Start I/O No.
Station No.
Set Controller
Load Flag
Data Bank No.
Variable name
Data type
i_bEN
Bit
i_bIeFieldFlag
Bit
Word
i_uStartIONo
[Unsigned]
Word
i_uStationNo
[Unsigned]
Word
i_uSetController
[Unsigned]
i_bLoadFlag
Bit
Word
i_uDataBankNo
[Unsigned]
SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
Valid range
ON, OFF
ON, OFF
Depends on the range of
the number of input/output
points of the target CPU
module. For more
information, refer to the
CPU User's Manual.
1 to 64 (in decimal) when
CC-Link IE Field Flag
(i_bIeFieldFlag) is OFF
1 to 120 (in decimal) when
CC-Link IE Field Flag
(i_bIeFieldFlag) is ON
16-bit data other than 0
ON, OFF
1 to 3
108/184
Description
Turn ON this label to start the FB. You
can exit from the FB by turning it from
ON to OFF.
Turn ON Execution Command (i_bEN)
with this flag OFF to start the FB on
SC-HG1-C or with this flag ON to start
the FB on SC-HG1-CEF.
Specify in hexadecimal the number of
the starting I/O where the target
CC-Link/CC-Link IE Field master/local
module is installed. (For example,
specify H0A0 if the starting I/O No. is
00A0.)
Specify the station number of the
communication unit you want to
configure.
Stores the word information (consisting
of 16 pieces of bit information) that
corresponds to the controller on which to
execute the command.
bit 0: Master device
bit 1: 1st slave device
to
bit 13: 13th slave device
bit 14: 14th slave device
bit 15: OFF (Not used)
When started with this flag ON, the FB
loads data bank.
When started with this flag OFF, the FB
saves data bank.
Specify the data bank number.
WUME-SCHG1IQRFB-1