Error code
(hexadecimal)
200
Remote READY flag OFF
Execution Command (i_bEN) turned OFF
201
before normal or error completion
Execution Command (i_bEN) was turned
from ON to OFF and then turned from
202
OFF to ON while Execution Status
(o_bENO) was ON
Input Signal (i_bInputSignal) is turned
203
from OFF to ON with Waiting Signal
(o_bSignalWait) OFF
FFFF
Module error occurrence
Description
SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
Check whether or not an error has occurred in the
communication unit. Check if the Start I/O
No.(i_uStartIONo) and the Station No. (i_uStationNo)
settings correctly indicate the target communication unit.
Check that Normal Completion (o_bOK) or Error
Completion (o_bErr) has turned ON and then turn OFF
Execution Command (i_bEN). This error code is output
also when Execution Command (i_bEN) is intentionally
turned OFF before completion.
Check that Execution Status (o_bENO) turned OFF and
then turn ON Execution Command (i_bEN).
Check that Waiting Signal (o_bSignalWait) is ON and
then turn ON Input Signal (i_bInputSignal). Teaching is
not executed but the teaching operation has been changed.
Check for any problem.
Check the Module Error Code (o_ud16ModuleErrId). For
information on module error codes, see "Appendix 2.4
Module error code (o_u16ModuleErrId) list".
48/184
Meaning