Panasonic SC-HG1 Series Reference Manual page 21

For mitsubishi melsec iq-r series sequencer
Table of Contents

Advertisement

Error code
■ List of error codes
Error code
(hexadecimal)
100
101
102
200
201
202
Description
The Station No. (i_uStationNo) is outside
the valid range
The information derived from the input
Start I/O No.(i_uStartIONo) and the
Station No. (i_uStationNo) is not
SC-HG1-C or SC-HG1-CEF.
CC-Link IE Field Flag (i_bIeFieldFlag) is
ON and Execution Command (i_bEN) is
ON
Remote READY flag OFF
Execution Command (i_bEN) turned OFF
before normal or error completion
Execution Command (i_bEN) was turned
from ON to OFF and then turned from
OFF to ON while Execution Status
(o_bENO) was ON
SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
Set the Station No. (i_uStationNo) to a value from 1 to
64.
Check if the Start I/O No.(i_uStartIONo) and the
Station No. (i_uStationNo) settings correctly indicate
the target communication unit.
Turn ON Execution Command (i_bEN) is ON with
CC-Link IE Field Flag (i_bIeFieldFlag) OFF.
Check whether or not an error has occurred in the
communication unit. Check if the Start I/O
No.(i_uStartIONo) and the Station No. (i_uStationNo)
settings correctly indicate the target communication
unit.
Check that Normal Completion (o_bOK) or Error
Completion (o_bErr) has turned ON and then turn
OFF Execution Command (i_bEN). This error code is
output also when Execution Command (i_bEN) is
intentionally turned OFF before completion.
Check that Execution Status (o_bENO) turned OFF
and then turn ON Execution Command (i_bEN).
21/184