Raytheon Anschütz NautoPilot 5000 Series Operator's Manual page 65

Table of Contents

Advertisement

Figure 20/5
Figure 20/6
Figure 20/7
Figure 20/5
and 7
Figure 20/8
Information about the changeover of NautoPilot® Operator Units, see section
6.3. Information on the test function, see section 2.3.7
Information on the alarm/status message handling, see section 7.
Edition: 003
DIM button
Adjusts brightness of illumination and display.
See also section 6.3 for dimming
active/inactive NautoPilot® Operator Units.
Acknowledges alarm or status messages.
ACK button with
LED (red blinking) indicates the first
LED (red)
occurrence of an alarm or status message
(blinking) or that an acknowledged alarm or
status message is still present (constant
glow).
In order to avoid unintended
acknowledgement of a new incoming alert,
the push button is deactivated for 1 second
after receiving a new alert.
SET button with
Sets changed parameters or adjusted values.
LED (yellow)
LED blinks to request the pressing of this
button.
DIM and SET
Activates the Test function if both buttons are
buttons
pressed simultaneously.
An interactive test (for the operator of the
NautoPilot® Operator Unit) is performed to
check the operating elements and the touch-
screen and its function.
Combined rotary
Presets a heading and activates adjusted set
knob/button
heading value.
49
NautoPilot® 5000 Series
102-890.NG001-NG003
Operator Manual
10000001052

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Np 5100Np 5300Np 5400Np 5500

Table of Contents