FAULT !
IntRelay
•
Internal Relay Fault – The internal transfer relay is not closing even
though the inverter is in Charge mode. Contact Magnum Technical Support
(425-353-8833) for assistance.
5.3.4
LED Indicator Guide
The remote provides the following LED statuses. Use them along with the LCD
display to determine the inverter/charger's operating status.
Table 5-1, LED Indicator Guide
LED
Status
OFF
INV
ON
(green)
BLINKING
OFF
FAULT
(red)
ON
©2013 Magnum Energy, Inc.
IntRelay appears on the LCD and
the FAULT (red) LED is on. The INV
(green) LED is off.
Figure 5-37, Internal Relay Fault
Meaning
1. Inverter is disabled; or 2. Remote is in Power
Saver mode – press any button to activate LEDs.
Inverter is enabled – 1. Supplying AC power on
the output; or 2. In Standby (a charge status
displays); the inverter will automatically supply
AC power to the loads if shore or generator
power is lost.
Inverter is in Search mode (the AC load is below
the Search Watts setting).
Normal operation.
A fault condition has been detected, check the
LCD display to fi nd and correct the cause.
5.0 Operation
35