Assa Abloy SARGENT IN120 Wi-Fi Series Installation Instructions Manual page 27

Exit device
Table of Contents

Advertisement

IN120 / IN220 Exit Device
3 Installation of Connectors
CAUTION - Do not allow debris to enter connector contacts
Ensure connectors are covered with silicone dielectric compound
Snip end of packet to dispense grease
Ensure all connector pins and contacts (Fig. 3A) are
covered - do not overfill or over-apply**
*Supplied tube contains 5 grams of silicone dielectric compound (grease)
**Evenly distribute grease; full application requires approximately 2.5 grams
IMPORTANT: Do not run wires through bottom hole in plate (Fig. 3A, B) - it will
damage wires and the controller connector. Route wires around flange, do not
route wires through the flange hole (Fig. 3B).
Secure the following connectors (Fig. 3A, B):
A. Secure the 4-pin DPS connector.
B. Secure the 10-pin lock body assembly connector.
Secure Mounting Plate
Tuck excess cable into wire hole on inside of door
Secure the mounting assembly while ensuring proper
alignment of outside reader and fully tighten the (2)
through-bolts on the inside of the door to secure the
reader and plate to the door
C. Secure the 24-pin card reader connector (Fig. 3B)
D. Ensure all openings on back of secured connectors are
covered completely with grease (Fig. 3C).
1-800-810-WIRE • www.sargentlock.com • A8185D
Important Note: Before you secure the connectors
SILICONE DIELECTRIC
COMPOUND
(grease)*
Reader
(24-pin)
Board-to-Board
Connector
D
FILL
27
APPLY
FILL
FILL
FILL
FILL
NO WIRES
THRU THIS
OPENING
Fig. 3A
A
C
B
Fig. 3B
FILL
Fig. 3C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sargent n220 poe series

Table of Contents