IN120 / IN220 Exit Device
3 Installation of Connectors
CAUTION - Do not allow debris to enter connector contacts
Ensure connectors are covered with silicone dielectric compound
•
Snip end of packet to dispense grease
•
Ensure all connector pins and contacts (Fig. 3A) are
covered - do not overfill or over-apply**
*Supplied tube contains 5 grams of silicone dielectric compound (grease)
**Evenly distribute grease; full application requires approximately 2.5 grams
IMPORTANT: Do not run wires through bottom hole in plate (Fig. 3A, B) - it will
damage wires and the controller connector. Route wires around flange, do not
route wires through the flange hole (Fig. 3B).
Secure the following connectors (Fig. 3A, B):
A. Secure the 4-pin DPS connector.
B. Secure the 10-pin lock body assembly connector.
Secure Mounting Plate
•
Tuck excess cable into wire hole on inside of door
•
Secure the mounting assembly while ensuring proper
alignment of outside reader and fully tighten the (2)
through-bolts on the inside of the door to secure the
reader and plate to the door
C. Secure the 24-pin card reader connector (Fig. 3B)
D. Ensure all openings on back of secured connectors are
covered completely with grease (Fig. 3C).
1-800-810-WIRE • www.sargentlock.com • A8185D
Important Note: Before you secure the connectors
SILICONE DIELECTRIC
COMPOUND
(grease)*
Reader
(24-pin)
Board-to-Board
Connector
D
FILL
27
APPLY
FILL
FILL
FILL
FILL
NO WIRES
THRU THIS
OPENING
Fig. 3A
A
C
B
Fig. 3B
FILL