Assa Abloy SARGENT IN120 Wi-Fi Series Installation Instructions Manual page 22

Exit device
Table of Contents

Advertisement

4 Position Exit Trim (ET)
NOTE: For exterior applications, use ET gasket (52-0263) as a seal between
ET escutcheon and outside door surface.
A. Connect motor harness adapter to chassis harness connector (Fig. 4A).
B. For wood doors: Route ET wire harness connector through the cylinder hole,
up and through the wire run channel to the controller cutout.
For metal doors: Route ET wire harness through the cylinder hole out the
controller cutout.
C. Pass top ET trim mounting post through chassis harness ground lug.
D. Ensure ET spindle engages the lower hub of the exit chassis.
E. Fully tighten (2) chassis through bolts (Fig. 4B).
Outside of Door
D
NOTE: Cable lengths exaggerated for illustrative purposes
B
C
A
Fig. 4A
22
IN120 / IN220 Exit Device
Fig. 4B
1-800-810-WIRE • www.sargentlock.com • A8185D
Inside of Door
Tighten
fully
E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sargent n220 poe series

Table of Contents