4 Mount Exit Trim (ET)
NOTE: For exterior applications, use ET gasket (52-0263) to seal between
ET escutcheon and outside door surface.
A. Connect motor harness adapter to chassis harness connector (Fig. 4A).
B. For wood doors: Route ET wire harness connector through the cylinder hole,
up and through the wire run channel to the controller cutout.
For metal doors: Route ET wire harness through the cylinder hole out the
controller cutout.
C. Pass top ET trim mounting post through chassis harness ground lug.
D. Ensure ET spindle engages the lower hub of the exit chassis.
E. Fully tighten (2) chassis through bolts (Fig. 4B).
Fig. 4B
Inside of Door
E
Tighten fully
16
IN120 / IN220 Exit Device
Outside of Door
D
Fig. 4A
1-800-810-WIRE • www.sargentlock.com • A8185D
C
B
A