Scsi Interface - Epson GT-10000+ User Manual

Color scanner
Hide thumbs Also See for GT-10000+:
Table of Contents

Advertisement

EMC
FCC part 15 subpart B class B
CSA C108.8 class B
AS/NZS3548 class B
CISPR Pub22 class B
CNS13438 class B
EN 55022 (CISPR Pub 22) class B
CE marking
Low Voltage Directive 73/23/EEC
EN 60950
EMC Directive 89/336/EEC
EN 55022 Class B
EN 61000-3-2
EN 61000-3-3
EN 50082-1
IEC 801-2
IEC 801-3
IEC 801-4

SCSI Interface

Interface type
ANSI X3T9.2/375R Revision 10L
(SCSI 2)
Functions
BUS FREE phase
ARBITRATION phase
SELECTION/RESELECTION phase
COMMAND phase (the Logical unit
number is fixed at 0 and the command
link function is not supported)
DATA phase
DATA IN phase
DATA OUT phase
STATUS phase
MESSAGE phase
MESSAGE IN phase
MESSAGE OUT phase
ATTENTION condition
RESET condition
Logic level
TTL compatible
Electrical standard
ANSI X3T9.2/375R
Revision 10L (SCSI 2)
ID setting
Can be set from 0 to 7
Terminator
Internal terminator selectable
(enable/disable)
Connector type
Two half-pitch 50-pin connectors
Connector pin arrangement:
25
50
Initialization Methods
The scanner can be initialized (returned to a
fixed set of conditions) in these ways:
Hardware initialization
When the scanner is turned on
When the scanner receives a SCSI Reset
signal from the SCSI interface
Software initialization
When the software sends the ESC @
(initialize the scanner) command
When the scanner receives a SCSI Bus
Device Message
1
26
123
Specifications