100 TROUBLESHOOTING

BATTERY TROUBLESHOOTING

Trouble
Starter does not function.
From beginning starter
does not function, and
lights soon become dim.
When viewed from top,
the top of plates look
whitish.
* Refillable type battery only
Recharging is impossible.
Terminals are severely
corroded and heat up.
Battery electrolyte level
drops rapidly.
* Refillable type battery only
A If you have any questions, consult your local KUBOTA Dealer.
A The factory-installed battery is non-refillable type.
Cause
A Battery overused until
lights are dim.
A Battery has not been
recharged.
A Poor terminal
connection.
A Battery life expired.
A Insufficient charging.
A Battery was used with
an insufficient amount
of electrolyte.
A Battery was used too
much without
recharging.
A Battery life expired.
A Poor terminal
connection.
A There is a crack or pin
holes in the electrolytic
cells.
A Charging system
trouble.
Countermeasure
A Charge battery
A Charge the battery properly.
sufficiently.
A Clean the terminal
A Keep the terminal clean and
and tighten securely.
A Renew battery.
A Charge battery
A Battery must be serviced
sufficiently.
A Add distilled water
A Regularly check the
and charge the
battery.
A Charge battery
A Charge the battery properly.
sufficiently.
A Replace battery.
A Clean the terminal
A Keep the terminal clean and
and tighten securely.
A Replace battery.
A Consult your local
KUBOTA Dealer.
Preventive measure
tight.
Apply grease and treat with
anti-corrosives.
properly before initial use.
electrolyte level.
tight.
Apply grease and treat with
anti-corrosives.