Required Equipment - Avaya Aura Communication Manager Branch i120 Installation, Quick Start

Advertisement

No more than 25 feet (7.6 m) from an approved ground or close enough for use with the
supplied secondary grounding conductor.
Note:
If the supplied secondary grounding conductor does not reach the approved
Note:
ground, you must contact a licensed electrician to install a supplementary ground
conductor.
The environmental conditions match the following requirements:
Ambient temperature - 32
Relative humidity - 10 to 90% relative humidity.
Minimum clearance for ventilation - 18 in. (45 cm).
Weight support - up to 40.5 lbs (18.4 kg).

Required equipment

Prepare the tools you need to mount the Communication Manager Branch i120 according to the
following table:
To mount
on...
Rack
Wall
You might also need wire cutters to attach the grounding conductors, if your site uses a
ground block.
To configure your Communication Manager Branch i120, you will need a computer with a
screen resolution of 1024x768 pixels or greater and either Internet Explorer 6.0 or Mozilla
Firefox 2.0 or later.
Unpack
The Communication Manager Branch i120 is shipped with the following items. If any items are
missing or damaged, contact your supplier. Retain the packaging in case you need to ship the
Communication Manager Branch i120.
2 Communication Manager Branch i120 Installation Quick Start
o
to 104
Phillips head screwdriver.
Plywood board: ¾ in (1.2 cm) thick and at least 4 x 4 ft (1.2 x
1.2 m) in size (to be supplied by the customer).
Wood screws (4 minimum).
Screws to fasten the Communication Manager Branch i120 to
the board.
o
o
o
F (0
to 40
C).
Prepare these tools