Volume Data Read Ahead; Hdd Queue Depth Setting - Areca ARC-1880 Series User Manual

6gb/s sas raid cards
Table of Contents

Advertisement

BIOS CONFIGURATION

3.7.5.8 Volume Data Read Ahead

The volume read data ahead parameter specifies the controller
firmware algorithms which process the read ahead data blocks
from the disk. The "Data Read Ahead" parameter is normal
by default. To modify the value, you must set it from the "
Raid System Function" using the 'Volume Data Read Ahead"
option. The default "Normal" option satisfies the performance
requirements for a typical volume. The "Disabled" value implies
no read ahead. The most efficient value for the controllers
depends on your application. The "Aggressive" value is optimal
for sequential access but it degrades random access.

3.7.5.9 Hdd Queue Depth Setting

This parameter is adjusted the queue depth capacity of NCQ
(SAS HDD) or Tagged Command Queuing (SAS HDD) which
transmits multiple commands to a single target without waiting
for the initial command to complete.
82
I/O Port Addr : 28000000h, F2(Tab): Select Controller, F10: Reboot System
Areca Technology Corporation RAID Controller
Raid System Function
Main Menu
Mute The Alert Beeper
Quick Volume/Raid Setup
Alert Beeper Setting
Raid Set Function
Change Password
Volume Set Function
JBOD/RAID Function
Physical Drives
Raid System Function
Background Task Priority
Raid System Function
SATA NCQ Support
Hdd Power Management
HDD Read Ahead Cache
Ethernet Configuration
Volume Data Read Ahead
Volume Data Read Ahead
View System Events
Hdd Queue Depth Setting
Clear Event Buffer
Empty HDD Slot LED
Hardware Monitor
Controller Fan Detection
System information
Auto Activate Raid Set
Disk Write Cache Mode
Capacity Truncation
ArrowKey Or AZ:Move Cursor, Enter: Select, ESC: Escape, L:Line Draw, X: Redraw
Volume Data Read Ahead
Normal
Enabled
Aggressive
Conservative
Disabled

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents