HARDWARE INSTALLATION
Figure 2-1, ARC-1880ix-12/16/24 6Gb/s SAS RAID controller
Connector
1. (J3)
2. (J4)
3. (CN1)
4. (J10)
5. (J7)
6. (J9)
7. (J11)
8. (J1)
9. (J2)
10. (SCN1)
11. (SCN2)
12. (SCN3)
13. (SCN4)
14. (SCN5)
15. (SCN6)
Table 2-1, ARC-1880ix-12/16/24 connectors
Note:
*1: You can download the ARC1880ix_1882ix Expander-CLI.
PDF manual from http://www.areca.com.tw/support/main.
htm.
Type
Battery Backup Module Connector
RS232 Port for CLI to configure the
expander functions on the RAID control-
ler (*1)
SAS 25-28 Ports (External)
Ethernet Port
Manufacture Purpose Port
Individaul Fault LED Header
Individual Activity (HDD) LED Header
Global Fault/Activity LED
I2C/LCD Connector
SAS 21-24 Ports (Internal)
SAS 17-20 Ports (Internal)
SAS 13-16 Ports (Internal)
SAS 9-12 Ports (Internal)
SAS 5-8 Ports (Internal)
SAS 1-4 Ports (Internal)
Description
12-pin box header
RJ11 connector
SFF-8088
RJ45
10-pin header
24-pin header
24-pin header
4-pin header
8-pin header
SFF-8087
SFF-8087
SFF-8087
SFF-8087
SFF-8087
SFF-8087
17