Event Notification Configurations; Device Event - Areca ARC-1880 Series User Manual

6gb/s sas raid cards
Table of Contents

Advertisement

APPENDIX
Appendix D

Event Notification Configurations

The controller classifies disk array events into four levels depend-
ing on their severity. These include level 1: Urgent, level 2: Serious,
level 3: Warning and level 4: Information. The level 4 covers notifica-
tion events such as initialization of the controller and initiation of the
rebuilding process; Level 2 covers notification events which once have
happen; Level 3 includes events which require the issuance of warning
messages; Level 1 is the highest level, and covers events that need
immediate attention (and action) from the administrator. The following
lists sample events for each level:
A. Device Event
Event
Device Inserted
Device Removed
Reading Error
Writing Error
ATA Ecc Error
Change ATA
Mode
Time Out Error
Device Failed
PCI Parity Error
Device
Failed(SMART)
176
Level
Meaning
Warning
HDD inserted
Warning
HDD removed
Warning
HDD reading error
Warning
HDD writing error
Warning
HDD ECC error
Warning
HDD change ATA
mode
Warning
HDD time out
Urgent
HDD failure
Serious
PCI parity error
Urgent
HDD SMART failure
Action
Keep Watching HDD status, may
be it caused by noise or HDD
unstable.
Keep Watching HDD status, may
be it caused by noise or HDD
unstable.
Keep Watching HDD status, may
be it caused by noise or HDD
unstable.
Check HDD connection
Keep Watching HDD status, may
be it caused by noise or HDD
unstable.
Replace HDD
If only happen once, it may
be caused by noise. If always
happen, please check power
supply or contact to us.
Replace HDD