SMT Information

This area of the FddiMAC Device Configuration
view provides the following configuration
information on the FDDI SMT:
SMT Version
The version of Station Management (SMT)
running.
OBS Present
Indicates whether an Optical Bypass Switch
(OBS) is connected.
T-Notify (sec)
The timer value, in seconds, used in Neighbor
Notification Protocol. The allowed range is from 2
to 30 seconds.
T-Req (milli sec)
The Target Token Rotation Time (TTRT) bid, in
milliseconds, made by this concentrator.
T-Neg (milli sec)
The winning TTRT bid, in milliseconds, on the
ring.
TVX (milli sec)
The valid transmission time, in milliseconds.
S p e c t r u m E n t e r p r i s e M a n a g e r
A T M C l i e n t C o n f i g u r a t i o n V i e w

ATM Client Configuration View

This view provides VPI/VPC configuration
information on the ATM interfaces.
Max VPCs (Virtual Path Connections)
The maximum number of VPCs supported at this
ATM interface. At the UNI (User Network
Interface), the maximum number of VPCs ranges
from 0 to 256.
Max VCCs (Virtual Channel Connections)
The maximum number of VCCs supported at this
ATM interface.
Conf VPCs
The number of VPCs configured for use at this
ATM interface. At the UNI (User Network
Interface), the configured number of VPCs ranges
from 0 to 256.
Conf VCCs
The number of VCCs configured for use at this
ATM interface.
Max VPI (Virtual Path Identifier) Bits
The maximum number of active VPI bits
configured for use at this ATM interface. At the
UNI (User Network Interface), the maximum
number of active VPI bits configured for use
ranges from 0 to 8.