C o n f i g u r a t i o n V i e w s
MAC Address
The MAC (physical) address of this station.
MAC Count
The number of MACs supported by this station.
Ring State
Isolated
The concentrator is not attached to the ring.
Non-Op
The concentrator is attempting to enter the ring.
Ring-Op
The ring is operational.
Detect
The claim/beacon process of the FDDI ring protocol has exceeded one second. This indicates a potential
problem.
Non-Op-Dup
The ring failed to complete the claim/beacon process because a duplicate FDDI address has been
detected.
Ring-Op-Dup
The ring is operational, but a duplicate FDDI address has been detected.
Directed
The claim/beacon process did not complete within nine seconds. The concentrator is now sending
directed beacons to indicate a problem.
Trace
A problem has been detected with the station or its upstream neighbor. A trace is being sent to notify the
upstream neighbor of the problem. The concentrator and all stations between the concentrator and its
upstream neighbor can perform self-tests.
S p e c t r u m E n t e r p r i s e M a n a g e r
Non Master Ports
The number of non-master ports on this station.
Master Ports
The number of master ports on this station.
Table 20: FDDI Ring Stats