4.1.3 Motor

Rated current %
Fig. 75
Start-up diagram (current and speed characteristics)
rpm
see name-
approx. 2 -
plate
* WS standard
The separator is driven by a three-phase AC motor via a centrifugal clutch and
the drive belt.
The specified motor ratings are minimum values which are based on the in-
creased starting current. Since the current consumption of the motor drops after
start-up, overloading of the motor during operation is not possible.
The starting time depends on the
– flywheel effect of the bowl,
– number of clutch shoes used,
– condition of the clutch shoes.
The starting current can peak at about 1.8–2 times the rated current (see start-
up diagram). This is to be considered when selecting switches, lead-in wires
and fuses.
The motor
– can be started direct on-line,
50 Hz 60 Hz
min
s
2
4
Westfalia Separator
Mineraloil Systems GmbH
Separation
Enclo-
De-
sign
sure
kW
IP 55
4
4.8
IM
ISO-
V1
class
F *
2058-9001-101 / 0506
Separation
at
50 Hz
60 Hz
*
rpm
rpm
3 000
3 600