Westfalia OSD 6-91-067 Instruction Manual page 163

Table of Contents

Advertisement

Westfalia Separator
Mineraloil Systems GmbH
2058-9001-101 / 0506
Technical data
Part-No.
Operating principles
Nominal width
Material:
Line connection:
Coil size
Voltage
Rating
Pressure
Coupler socket
Temperature:
In case of electrical faults
• Switch off main switch.
• Shut off main valve for operating water.
Problem
Cause
Valve does not
Control unit is defective.
function.
Wire break in the connect-
ing terminal.
Connecting terminal on the
connector block is loose.
Bad contact on the con-
necting terminal.
Coupler socket loose.
Magnet coil defective.
Diaphragm defective.
0018-6654-000
2/2-way valve normally closed
13 mm
Gasket
EPDM
Housing
CuZn
Input
G 3/4 in sleeve
Output
G 1/2 in sleeve
32 mm
24 V DC
8 W
Medium
0.2 -16 bar
with built-in electronics,
24 VDC, LED and free-wheeling diode
with fitted cable (1.5 m long)
Medium
-10 to +80 °C (14 – 176 °F)
Ambient
max. +35 °C (95 °F)
Action
Contact service backup
support.
Replace wire.
Tighten the screw of the
connecting terminal.
Clean or replace the con-
tact.
Tighten coupler socket.
Replace the solenoid head.
Replace diaphragm.