Module 6022
Cause
The detector has received a
request for an unknown data set.
The detector has received a
change message for an unknown
data set.
The detector has received a
command message indicating an
unknown command.
Fault and Error Diagnosis
Actions
1. Check the controlling
device for reported errors.
1. Check the controlling
device for reported errors.
1. Check the controlling
device for reported errors.