Run Errors
Are classified as non-fatal but requires an operator's attention. When an error is
generated the attention relay operates and subsequently any remote device connected
to it. In addition the Run Error LED
detector is fitted with the Reports/Logs package the errors can be accessed in the Run
Error menu "View errors". All errors are described as either passive (PSV), active
(ACT) or as an event (EVT) the date & time accompany errors.
Message
PV test
prompt
Pec blocked
Neg delay
exten
Speed too fast
Speed too
slow
Reject too
close
Reject
disabled
Note: PEC = Photo Electric Cell or Photoeye.
Module 6022
! ! ! !
Cause
A programmed PVS test
prompt has occurred.
PEC has remained blocked for
5 consecutive pack lengths.
Product registration photoeye
only.
Reject dwell time setting
problem. Variable speed
systems only.
Belt speed is greater than the
upper limit for existing filter
resistors, coil gap and belt
speed. Variable speed systems
only.
Belt speed is less than the
lower limit for existing filter
resistors, coil gap and belt
speed. Variable speed
systems.
The reject system is still
counting out the dwell for a
reject when the next pack to be
rejected comes along
The reject relay has been
disabled.
on the User Interface illuminates. If your
Solution
1. Complete a PV Test.
1. Check the PEC for
blockage.
2. Check PEC is
working.
3. Check pack flow
length entry is adequate,
ensuring an allowance is
made for pack skewing.
4. Ensure correct belt
speed is entered.
1. Check reject delay
and dwell time settings.
1. Decrease belt speed.
2. Change filter resistors
to lower value. Refer to
"Belt Speed"
the "Configuration &
Setup" section of this
manual
1. Increase belt speed.
2. Change filter resistors
to higher value. Refer to
"Belt Speed"
the "Configuration &
Setup" section of this
manual
1. Reduced the reject
dwell time.
2. Improve the pack
pitch.
3. If the reject is a
retracting band or
lift/drop flap, change the
reject mode to pulse
extension.
1. Enable the reject
relay using the Reject
enable command.
PVS = Performance Validation System.
Fault and Error Diagnosis
LomaLink
Error No.
22
23
24
25
in
on page 14
26
in
on page 14
27
29
4-3