Verify hoses are connected as outlined in the schematic below.
TR
TEST
24. On the FDT Panel, click the Component Pressure Test button.
The Get FDT Status button may be clicked to examine FDT status.
NOTE: The pressure testing will last for 4 minutes (2 minutes with air pump on)
CAUTION: This unit must not be left running unattended, service personnel
should always be overseeing the process. (C038)
25. Click the Get FDT Status button and review the following:
• Tool mode:
• Error Status:
• Component Pressure Test: Pass – OK. Proceed to next step.
26. The component pressure test has passed successfully.
Power775 Disk Enclosure Chassis Service Procedure
----Appendix A: DE Pressure Test Procedure ----
HA2
HA1
Ready – OK. Check Error Status.
System/Component Pressure Test Mode – pressure test
still running.
Wait 30 seconds and repeat Step 25.
NONE – OK. Check Component Pressure Test.
WARNING – click the Decode Error Status button, record
information returned and proceed to next step.
CRITICAL – click the Decode Error Status button, record
information returned and contact next level of support.
Fail or Incomplete – action required.
Click the Reset FDT button.
Repeat Step 19 through Step 24 and continue
with procedure.
If the test read Fail twice, hardware is
defective. Contact next level of support.