STEP 37
Ensure that the UEPO will not be hit as the table moves up and down. Also ensure that the UEPO
is secured to the frame so it does not move during the service procedure.
STEP 38
Raise the lift tool table just below the DE to be removed. The platform is raised via the Table Lift
Drive, using the battery powered drill shipped with the Lift Tool, and a 5/16" hex socket.
ATTENTION:
Use two hands to operate the battery powered drill as it is a high torque tool (see Figure
34).
Use the "Drill" setting on speed "LOW (1)" (Figure 35).
Be aware that when lowering the tool, as you approach the bottom of the lift table range,
reduce the speed of the drill to avoid high torque to the hands and drill slippage from
the tool.
Required Tools:
Milwaukee Cordless Drill 2602-20 & Milwaukee 18V Lithium-ION Battery 48-11-1828
Power775 Disk Enclosure Chassis Service Procedure
Figure 32: Lift Table Movement Path
Figure 33: Secure Cables