Voltage Monitor Output - Kikusui PLZ-4WH Series User Manual

Table of Contents

Advertisement

Voltage monitor output

The signal is output from the V MON OUT connector on the PLZ-4WH front panel and across
pins 4 and 6 (pin 6 is common) of the EXT CONT connector.
To avoid damaging the product, observe the following precaution. Pin 6 of the EXT CONT
CAUTION
connector is connected to the negative load input terminal. Make sure that the wire of pin 6
does not touch any of the other pins.
Monitor output
The common is connected to A COM. For the 650 V and 65 V ranges, 10 V corresponds to
the full scale voltage. The output impedance is 1 kΩ.
PLZ-4WH
10 V
0
Voltage
V MON OUT connector (BNC) on the PLZ-4WH front panel
Front panel
V MON OUT
Across pins 4 and 6 of the EXT CONT connector
Full scale of the range
The common is connected to the chassis electric
potential. It is isolated from A COM. For the 650 V and
65 V ranges, 6.5 V corresponds to the full scale
voltage. The maximum output current is 5 mA.
Monitor Signal Output
103
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plz164whPlz334whPlz1004whPlz4004whbPlz2004wb

Table of Contents