Ac Pow. Output, Ac Pow. Output Voltage, Ac Pow. Output Frequency, And Ac Pow. Voltage Range - Kikusui KHA1000 Operation Manual

Harmonic/flicker analyzer
Hide thumbs Also See for KHA1000:
Table of Contents

Advertisement

WARNING
4.5.1
AC Pow. OUTPUT, AC Pow. Output Voltage,
AC Pow. Output Frequency, and AC Pow. Voltage Range
Menu
Page 1/1
AC Pow.
F1
OUTPUT
This menu turns on/off the AC Power Supply OUTPUT.
In the ON state, the icon in the upper part of the display shows a turned-on light
Page 4-13
See
bulb.
AC Pow.
F2
Output Volts
This menu sets the AC Power Supply output voltage. The setting range is from 0.0
V to 305.0 V. It corresponds to the F4 AC Pow. Voltage Range. The setting should
be in accordance with the power rating of the EUT.
AC Pow.
F3
Output Freq
This menu sets the AC Power Supply output frequency. Select 50 Hz or 60 Hz
according to the power rating of the EUT.
AC Pow.
F4
Voltage Range
This menu sets the AC Power Supply output voltage range.
The 100 V range is used when the output voltage setting range is from 0 V to 152.5 V.
The 200 V range is used when the output voltage setting range is from 0 V to 305.0 V.
4-20
To prevent an electric shock, do not touch the SOURCE and LOAD
terminals of this product.
Do not touch the OUTPUT terminal of the AC Power Supply.
Do not touch the INPUT and OUTPUT terminals of the Line
Impedance Network.
F 1
F 1
F 2
F 2
F 3
F 3
F 4
F 4
F 5
F 5
F 6
F 6
ON
numeric
value
50 Hz
60 Hz
100 V
200 V
OFF
KHA1000

Advertisement

Table of Contents
loading

Table of Contents